YL4560 45/0 Non-Contact Benchtop Spectrophotometer
Specification
Model | YL4560 |
Optical Geometry | 45/0 method(45 ring-shaped illumination, vertical viewing);Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833,ISO7724-1,ASTM E1164,DIN5033 Teil7,GB 2893,GB/T 18833 |
Features | 45/0 non- contact benchtop spectrophotometer can achieve precise non- contact measurement between the measuring probe and the sample like liquids, sauces, powders, etc. It can be applied for accurate color analysis and transmission In laboratories and R & D industries; It can also be used for accurate color measurement and quality control of automated production lines; It is widely used in cosmetics, fruits and vegetables, food hygiene, plastic electronics, paint and ink, printing, ceramics and other industries, and also for fluorescence sample measurement. |
Light Source | Full spectrum LED light,UV light |
Spectrophotometric Mode | Concave Grating |
Sensor | 256 Image Element Double Array CMOS Image Sensor |
Wavelength Range | 400~700nm/10nm output |
Reflectance Range | 0~200% |
Measuring Aperture | Φ20mm(can be customized <20mm) |
Non-contact Distance | 7.5mm |
Sample Height | 0~150mm |
Distance Adjustment Method | Manual adjustment and automatic adjustment (test height can be stored) |
Measuring mode | Sample mode/QC Mode/Continuous statistics mode |
Locating Method | Camera Locating |
Color Space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,HunterLAB |
Color Difference Formula | ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00,ΔE(Hunter) |
Other Colorimetric Index | WI(ASTM E313,CIE/ISO,AATCC,Hunter),YI(ASTM D1925,ASTM 313),TI(ASTM E313,CIE/ISO), Metamerism Index MI,Staining Fastness,Color Fastness,Color Strength, Opacity |
Observer Angle | 2°/10° |
Illuminant | D65,A,C,D50,D55,D75, F1,F2(CWF),F3,F4,F5, F6,F7(DLF),F8 ,F9,F10(TPL5),F11(TL84),F12(TL83/U30) |
Displayed Data | Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, Chromaticity Graph, Color Simulation, PASS/FAIL Result, Color Offset |
Measuring Time | About 1.5s |
Data Storage | Sample mode + QC mode: 40,000; Continuous statistics mode: 10,000 |
Repeatability |
Spectral reflectance: Standard deviation within 0.08% Chromaticity value: Within ΔE*ab 0.03 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration) |
Inter-instrument Error | Within ΔE*ab 0.2(Average for 12 BCRA Series II color tiles) |
Measurement Mode | Single Measurement, Average Measurement(2 ~ 99 times) |
Dimension | 330*250*370mm |
Weight | About 10 kg |
Power Supply | DC 24V, 3A Power Adapter |
Illuminant Life Span | 5 years, more than 3 million times measurements |
Display Screen | 7" TFT Capacitive Screen-touch Display |
Data Port | USB/RS-232,Bluetooth®4.0 |
Language | Simplified Chinese,Traditional Chinese,English |
Working Environment | Temperature: 0~40℃; Humidity: 0~85% (No Condensation); Altitude < 2000m |
Storage Environment | Temperature: -20~50℃; Humidity: 0~85% (No Condensation) |
Standard Accessory | Power Adapter, User Manual, USB cable, Standard Calibration Board, Black Calibration Cavity, |
Notes | The specifications are subject to change without notice. |
Model: YD5050 Plus Introduction: 3nh launched new model YD5050 Plus Grating Spectrophotometer Densitometer with 45/0(45 ring-shaped illumination, 0 degree viewing angle), comply to standard ISO 5-4,CIE No.15. It is suitable for using in ink printing, in Film Processing, Textile Printing and Dyeing, Plastic Electronics and Other Industries for Color Measurement and Quality Control;especially suitable for the measurement and quality control of optical density and dot enlargement in ink printing. Under the 45/0 geometric optical illumination and the testing conditions of M O, M 1,M 2 , M 3 stipulated by ISO 13655 standard, the instrument can accurately measure the reflectance data of samples. Under multiple color spaces, it can accurately measure various printing density indexes, color difference formulas and color indexes, and can meet the user's regular testing of various parameters.