Milk Analyzer MA-1034

Milk Analyzer MA-1034

Milk Analyzer
Model: MA-1034
Manufacturer: Scitek - China
Contact for quote: 0765 259 545
The milk analyzer is used in dairy laboratories to analyze the composition and quality of milk to make quick analyses of milk on fat (FAT), non-fat solids (SNF),proteins, lactose and water content percentages, temperature (°C), freezing point, salts, total solids and density.

Ứng dụng:

Milk Analyzer 
Model: MA-1034
Manufacturer: Scitek - China 
Laboratory Milk Analyzer Features:
Large LCD display screen.
Testing time: 60-90 seconds.
Reserve wearable silicone tube
Also test milk, ewe's milk, UHT milk
Convenience to carry out, and could be use with auto battery
Simple operation for maintenance, calibration and installation
Very small quantity of milk sample is required
Low consumption
No use of hazardous chemicals
Measuring accuracy adjustment can be done by the user RS 232 Interface
Standard with printer
Specifications:
Model
MA-1034
Display
LCD display (4 lines*16 characters)
Testing Time
60-90 seconds
Environmental Conditions
Ambient Air Temperature
- 10°C -40°C
Milk Temperature
- 1°C - 40°C
Relative Humidity
- 30% - 80%
Interface
RS232
Printer
Standard
Power Supply
100~240V, 50/60Hz
DC Power Supply
12V to 14.2V
Power
36W
Size(W×D×H)(mm)
Milk Analyzer: 150×170×170
Printer: 150×200×120
Shipping Size(W×D×H)(mm)
320×320×400(includes printer)
N.W./G.W. (kg)
2/3.5 (Includes printer)
 
Parameters of Analysis:
Parameters
Measuring range
Accuracy
Fat
0.01–25%
±0.1%
Solids-non-fat (SNF)
3%–15%
±0.15%
Density
1015–1160 kg/m3
±0.3kg/m3
Protein
2%–7%
±0.15%
Lactose
0.01%–6%
±0.2%
Added Water
0%–70%
±3
Milk Sample Temperature
1°C–40 °C
±1%
Freezing Point
-0.4°C–0.7°C
±0.001%
Solids
0.4%–1.5%
±0.05%
Product Similar
Benchtop Class N Autoclave Model: ST-B18NI Manufacturer: Scitek - China Contact for quote: 0765 259 545 Benchtop Class N Autoclave Features: Complies with European Class N standard for sterilization effectiveness. Microcomputer control system for automatic cycle programming and temperature setting (121℃ and 134℃). User-friendly interface with touch buttons for easy operation. Safety interlocking device to prevent opening of the cover during pressurization or high temperature. Class N autoclave equipped with a standard test interface for additional functionality. Quality stainless steel inner tank and sealed cover for durability and airtight operation. Open-type top water tank for convenient water filling. Automatic protection functions, including over-temperature, over-pressure, low water level, and anti-dry burning. Buzzer reminder and automatic stop after sterilization. Automatic discharge of cold air and steam exhaust after sterilization. Built-in steam generator for quick production of saturated steam.

0765 259 545

Biological Safety Cabinet Model : BSC-IIB2-2F Manufacturer: Scitek - China Contact for quote: 0765 259 545 Class II B2 Biosafety Cabinet Features: UV sterilization function and timing function can be set by appointment. Motorized front window, control limit and travel limit double protection, ergonomic 10° tilt Angle, improve the operation comfort. With memory function in case of power-failure. Work area surrounded by negative pressure, prevent leakage,improve Biosafety. Audio and visual alarm (Abnormal airflow velocity, HEPA filter failure, UV lamp failure, Front window at unsafe height). Interlock function: UV lamp and front window; UV lamp and blower, LED lamp; blower and front window. Standard with foot switch: adjust front window to up and down, to avoid airflow turbulence caused by arm movement.

0765 259 545

Horizontal Pressure Steam Autoclave Model: ST-H100 Manufacturer: Scitek - China Contact for quote: 0765 259 545 Horizontal Pressure Steam Autoclave Features: Overheat protection: Automatically cutting off heating with audible and visual alarming when the autoclave is overheated. Electric interlock safety: Preventing from starting a cycle if door is not properly locked or from door opening if the chamber is pressurized or the power is disconnected. Door-temperature interlock safety: Preventing from explosion of liquids if the liquids temperature is not cooled down the safe limit (20℃ lower than the local boiling point). Anti-burning protection: Automatically cutting off heating with audible and visual alarming when the autoclave is lack of water. Steam pressure safety valve: Automatically works when the chamber pressure exceeds the limit. Electrical circuit safety device for over-current and shortcut protection. Automatic operation of sterilization (heating, sterilization, steam discharge and drying) can be easily set and monitored by the LCD touch screen. Built-in steam generator prevents the media from contamination. Buzzer for working errors and the end of the cycle. Automatic atmospheric pressure adjustment for the installation and operation in plateau areas. Optional printer, real-time record sterilization process, error and alarm information.

0765 259 545

Portable Dissolved Oxygen Meter P820 Model: P820 Manufacturer: Scitek - China Contact for quote: 0765 259 545 DO-P820/821 is one of the most popular handheld DO meters. The DO-P820 dissolved oxygen meter is cheaper and has lower accuracy than the P821, suitable for use in aquaculture. The P821 not only has high accuracy and supports 500 sets of data storage, but also has a limit value protection function. When exceeding the high and low limit values, the machine will automatically warn and remind. If there are any other problems besides the above differences when purchasing a dissolved oxygen meter, you can choose the P820 at an affordable price.

0765 259 545

Benchtop Class B Autoclave Model: ST-B18B Manufacturer: Scitek - China

0765 259 545

Single-head Gluten Tester Model: GT-SA Manufacturer: Scitek - China Contact for quotation: 0765 259 545

0765 259 545

Benchtop COD Analyzer Model: COD-1001 Manufacturer: Scitek - China Contact for quote: 0765 259 545

0765 259 545

Horizontal Pressure Steam Autoclave Model: ST-H450 Manufacturer: Scitek - China Contact for quote: 0765 259 545 Horizontal Pressure Steam Autoclave Features: Overheat protection: Automatically cutting off heating with audible and visual alarming when the autoclave is overheated. Electric interlock safety: Preventing from starting a cycle if door is not properly locked or from door opening if the chamber is pressurized or the power is disconnected. Door-temperature interlock safety: Preventing from explosion of liquids if the liquids temperature is not cooled down the safe limit (20℃ lower than the local boiling point). Anti-burning protection: Automatically cutting off heating with audible and visual alarming when the autoclave is lack of water. Steam pressure safety valve: Automatically works when the chamber pressure exceeds the limit. Electrical circuit safety device for over-current and shortcut protection. Automatic operation of sterilization (heating, sterilization, steam discharge and drying) can be easily set and monitored by the LCD touch screen. Built-in steam generator prevents the media from contamination. Buzzer for working errors and the end of the cycle. Automatic atmospheric pressure adjustment for the installation and operation in plateau areas. Optional printer, real-time record sterilization process, error and alarm information.

0765 259 545

Economic UV-VIS Spectrophotometer Model: SP-UV752E Manufacturer: Scitek - China Contact for quote: 0765 259 545

0765 259 545