Pipe Fittings Valve Pressure Drop Testing Machine
Model: JJPDTM-112
This instrument is mainly used for polyolefin (including PE, PP, PB, PIB, EPR, EPDM, etc.), polyvinyl chloride (including PVC-U, PVC-C, etc.), polyvinyl fluoride and other plastics The determination of the relationship between gas flow and pressure drop in piping system components such as pipe fittings and valves. This machine has the characteristics of automatic and procedural testing process, simple operation, safe operation and low noise.
Standard: GB/T 15558.3
Automatic Vertical Autoclave
Model: ST-V150A
Manufacturer: Scitek - China
Contact for quote: 0765 259 545
Automatic Vertical Autoclave Features:
Overheat protection: Automatically cutting off heating with audible and visual indication when the autoclave is overheated.
Anti-burning protection: Automatically cutting off heating with audible and visual indication when the autoclave is lack of water.
Interlock safety: Preventing from starting a cycle if door is not properly closed or from door opening if there is pressure inside chamber.
Steam pressure safety valve: Automatically works when the chamber pressure exceeds the limit.
Automatic operation of sterilization with PID microprocessor control and LCD display.
Positive pulsing function removes the air efficiently.
Liquid program with automatic pressure control prevents boil over of liquids and explosions of bottles or bags.
With Power-off memory function.
Internal water tank with steam-water internal circulation.
Standard printer, real-time record sterilization process,error and alarm information.
Horizontal Pressure Steam Autoclave
Model: ST-H60
Manufacturer: Scitek - China
Contact for quote: 0765 259 545
Horizontal Pressure Steam Autoclave Features:
Overheat protection: Automatically cutting off heating with audible and visual alarming when the autoclave is overheated.
Electric interlock safety: Preventing from starting a cycle if door is not properly locked or from door opening if the chamber is pressurized or the power is disconnected.
Door-temperature interlock safety: Preventing from explosion of liquids if the liquids temperature is not cooled down the safe limit (20℃ lower than the local boiling point).
Anti-burning protection: Automatically cutting off heating with audible and visual alarming when the autoclave is lack of water.
Steam pressure safety valve: Automatically works when the chamber pressure exceeds the limit.
Electrical circuit safety device for over-current and shortcut protection.
Automatic operation of sterilization (heating, sterilization, steam discharge and drying) can be easily set and monitored by the LCD touch screen.
Built-in steam generator prevents the media from contamination.
Buzzer for working errors and the end of the cycle.
Automatic atmospheric pressure adjustment for the installation and operation in plateau areas.
Optional printer, real-time record sterilization process, error and alarm information.
YT-LX1400 Digital Centrifugal Dryer
Model: YT-LX1400
Brand Name: YANTE - CHINA
Digital Centrifugal Dryer is mainly used for drying and dehydrating diapers. It is a professional dehydrator used in the diaper industry. It is also widely used in papermaking, textile, printing and dyeing and other industries. It is an indispensable auxiliary equipment in their production sites and laboratories.
application range.
Diapers, diapers, sanitary napkins, etc.
product function.
Diapers, diaper water retention test
product features.
● Small vibration, low noise, high dehydration efficiency
● ARM processor, 128×64 graphic dot matrix LCD display, Chinese display, simple operation
● Real-time display of speed and centrifugal force
● Adopt closed-loop AC motor speed regulation technology, convenient speed regulation and stable speed
● Contains brake function, can stop quickly, increase experimental accuracy and improve experimental efficiency
RCP Rapid Crack Propagation Tester
Model: RCP
Manufacturer: JJTest - China
Contact for quotation: 0765 259 545
RCP is used to determine arrest or propagation of a crack initiated in a thermoplastic pipe intended for the supply of gases or liquids at a specific temperature and internal pressure-Small-scale steady-state test (S4 test).
Standard; GB/T 19280; ISO 13477
Class B Autoclave, Automatic Door
Model: ST-BA45B
Manufacturer: Scitek - China
Complies with European Class B standard for effective sterilization.
Automatic door switch for convenient and safe operation.
Microcomputer control with LED display ensures precise and reliable sterilization.
Equipped with BD test, HELIX test, and Vacuum test for comprehensive sterilization performance.
Standard test interface for convenient testing and validation.
Automatic protection function includes over temperature, over pressure, low water level, anti dry burning, and safety door lock.
Safety interlocking device for secure operation.
Three times pre-vacuum enhances sterilization efficiency.
Buzzer reminder and automatic stop after sterilization cycle completion.
Automatic discharge of cold air and steam exhaust for efficient and safe operation.
Built-in steam generator provides quick production of saturated steam.
Built-in printer for record-keeping and documentation.
Milk Analyzer
Model: MA-1034
Manufacturer: Scitek - China
Contact for quote: 0765 259 545
The milk analyzer is used in dairy laboratories to analyze the composition and quality of milk to make quick analyses of milk on fat (FAT), non-fat solids (SNF),proteins, lactose and water content percentages, temperature (°C), freezing point, salts, total solids and density.
YT-XSL200 Klemm Capillary Rise Tester
Model: YT-XSL200
Brand Name: YANTE - CHINA
Product Details
product features
● Made of stainless steel, not prone to corrosion
● The sink is made of plexiglass
executive standard.
ISO8787-86,GB/T461.1-2002