HI98192

HI98192

Ứng dụng:

Measurement Ranges and Specifications

  • Conductivity (EC) Range:

    • 0.000 to 9.999 μS/cm* (do not use 4m electrode at this range)
    • 10.00 to 99.99 μS/cm; 100.0 to 999.9 μS/cm;
    • 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm;
    • 100.0 to 1000.0 mS/cm (real conductivity; temperature compensation up to 400 mS/cm)
  • EC Resolution: 0.001 μS/cm; 0.01 μS/cm; 0.1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm

  • EC Accuracy: ±1% of measured value (±0.01 μS/cm or 1 digit, whichever is larger)

  • EC Calibration: Automatic up to 5 points with optional 7 points (0.00 μS/cm, 84.0 μS/cm, 1.413 mS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm)

  • Total Dissolved Solids (TDS) Range:

    • 0.00 to 99.99 ppm; 100.0 to 999.9 ppm;
    • 1.000 to 9.999 ppt (g/L); 10.00 to 99.99 ppt (g/L); 100.0 to 400.0 ppt (g/L)
  • TDS Resolution: 0.01 ppm; 0.1 ppm; 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L)

  • TDS Accuracy: ±1% of measured value (±0.05 mg/L (ppm) or 1 digit, whichever is larger)

  • Resistance Range:

    • 1.0 to 99.9 Ω•cm; 100 to 999 Ω•cm;
    • 1.00 to 9.99 KΩ•cm; 10.0 to 99.9 KΩ•cm;
    • 100 to 999 KΩ•cm; 1.00 to 9.99 MΩ•cm; 10.0 to 100.0 MΩ•cm;
  • Resistance Resolution: 0.1 Ω•cm; 1 Ω•cm; 0.01 KΩ•cm; 0.1 KΩ•cm; 1 KΩ•cm; 0.01 MΩ•cm; 0.1 MΩ•cm*

  • Resistance Accuracy: ±1% of measured value (±10 Ω or 1 digit, whichever is larger)

  • Salinity Range:

    • % NaCl: 0.0 to 400.0%;
    • Practical salinity: 0.00 to 42.00 (PSU);
    • Natural seawater ratio - UNESCO 1966: 0.00 to 80.00 (ppt)
  • Salinity Resolution: 0.1%; 0.01

  • Salinity Accuracy: ±1% of measured value

  • Salinity Calibration:

    • 1 point according to % (HI7037 standard solution sold separately)
    • Or use conductivity calibration for PSU and ppt range
  • Temperature Range: -20.0 to 120.0°C (-4.0 to 248.0°F)

  • Temperature Resolution: 0.1°C (0.1°F)

  • Temperature Accuracy: ±0.2°C; ±0.4°F (including probe error)

  • Temperature Calibration: 1 or 2 points

  • Temperature Compensation: None, linear (-20 to 120 °C; -4 to 248°F), Nonlinear - ISO/DIN 7888 (-0 to 36 °C; 32 to 96.8°F)

  • Measurement Modes: Auto range, autoend, lock, and fixed modes

  • Reference Temperature: 15°C, 20°C, and 25°C

  • Temperature Coefficient: 0.00 to 10.00 %/°C

  • TDS Coefficient: 0.40 to 1.00

  • Electrode: HI763133 conductivity/TDS/resistance/salinity 4-ring with internal temperature sensor and 1m cable (included)

  • Data Logging: On-demand recording: 400 samples; Logging intervals: 5, 10, 30 seconds, 1, 2, 5, 10, 15, 30, 60, 120, 180 minutes (up to 1000 samples)

  • Configuration: Up to 10 configurations

  • PC Connectivity: Via USB port

  • Battery: (4) x 1.5V / approximately 100 hours of continuous use (no backlight), 25 hours with backlight

  • Auto Shut-Off: Options: 5, 10, 30, 60 minutes or off

  • Environmental: 0 to 50°C (32 to 122°F); 100% RH (IP67)

  • Dimensions: 185 x 93 x 35.2 mm

  • Weight: 400 g

 

Product Similar