Refractometer for Measuring NaCl in Food HI96821

Refractometer for Measuring NaCl in Food HI96821

Refractometer for Measuring NaCl in Food HI96821

Ứng dụng:

Refractometer for Measuring NaCl in Food HI96821

  • Salinity Range:

    • 0 to 28 g/100 g
    • 0 to 34 g/100 mL
    • 1.000 to 1.216 Specific Gravity
    • 0 to 26 °Baume
  • Salinity Resolution:

    • 0.1 g/100 g
    • 0.1 g/100 mL
    • 0.001 Specific Gravity
    • 0.1 °Baume
  • Salinity Accuracy (@20ºC/68ºF):

    • ±0.2 g/100 g
    • ±0.2 g/100 mL
    • ±0.002 Specific Gravity
    • ±0.2 °Baume
  • Temperature Range: 0 to 80°C (32 to 176°F)

  • Temperature Resolution: 0.1°C (0.1°F)

  • Temperature Accuracy: ±0.3°C (±0.5°F)

  • Temperature Compensation: Automatic from 0 to 40°C (32 to 104°F)

  • Measurement Time: Approximately 1.5 seconds

  • Minimum Sample Size: 100 μL (to fully cover prism surface)

  • Light Source: Yellow LED

  • Sample Chamber: Stainless steel ring and glass prism

  • Auto Shut-off: After 3 minutes of inactivity

  • Casing: IP65

  • Battery: 1 x 9V battery / approximately 5000 measurements

  • Dimensions: 192 x 102 x 67 mm

  • Weight: 20 g

Product Similar
Handheld pH/ORP/Temperature Meter Model: HI8314-1 Manufacturer: Hanna

0765 259 545

The HI9810432 is a professional, accurate and easy to use cordless pH meter from Hanna Instruments. - Specially designed to measure pH directly in cosmetic cream samples - Special junction prevents clogging - Accuracy of ±0.02 pH - Meter comes complete with calibration solutions, rinsing, filling, storage and batteries - Non-removable, pointed glass probe
4490000
Advanced Conductivity Benchtop Meter HI6321 is a streamlined Conductivity/Resistivity/Total Dissolved Solids (TDS)/Salinity/Temperature benchtop meter with a large touch screen display, comprised of a housing and an integrated conductivity measurement module. Compact and easy to operate, the HI6321 includes Hanna’s HI7631233 four-ring conductivity/resistivity/TDS/salinity probe. Recommended for a wide range of industrial process water applications, HI7631233 provides stable measurements over a wide measurement range and does not require frequent calibrations. An integral temperature sensor measures the process temperature and adjusts the measured conductivity to a reference temperature by applying specialized compensation algorithms: Linear: appropriate when it is assumed that the temperature coefficient of variation has the same value for all measurement temperatures. Standard: appropriate for high-purity water measurements and documented in ASTM Standard D5391-14. This setting should be used for >1Mohm.cm resistivity measurements. Natural: appropriate for natural ground, well, or surface water (or water with similar composition) in accordance with ISO7888 standard.

0765 259 545