bench-top turbidity meter HI88703-02

bench-top turbidity meter HI88703-02

bench-top turbidity meter HI88703-02

Ứng dụng:

bench-top turbidity meter HI88703-02    

  • Non-ratio mode range: 0.00 to 9.99 NTU; 10.0 to 40.0 NTU; 0.0 to 99.9 Nephelos; 100 to 268 Nephelos; 0.00 to 9.80 EBC.
  • Non-ratio mode resolution: 0.01 NTU; 0.1 NTU; 0.1 Nephelos; 1 Nephelos; 0.01 EBC.
  • Ratio mode turbidity range: 0.00 to 9.99 NTU; 10.0 to 99.9 NTU; 100 to 4000 NTU; 0.0 to 99.9 Nephelos; 100 to 26800 Nephelos; 0.00 to 9.99 EBC; 10.0 to 99.9 EBC; 100 to 980 EBC.
  • Ratio mode turbidity resolution: 0.01 NTU; 0.1 NTU; 1 NTU; 0.1 Nephelos; 1 Nephelos; 0.01 EBC; 0.1 EBC; 1 EBC.
  • Range selection: Automatic.
  • Accuracy: ±2% of the reading value plus 0.02 NTU, ±5% for values above 1000 NTU.
  • Repeatability: ±1% of the reading value.
  • Indicator light: Silicon photocell.
  • Calibration: 2, 3, or 4-point calibration.
  • Environment: 0 to 50°C; RH max 95% non-condensing.
  • Power supply: 230 V/50 Hz, automatic shutdown after 15 minutes of inactivity.
  • Dimensions: 230 x 200 x 145 mm.
  • Weight: 2.5 kg.
Product Similar
Handheld pH/ORP/Temperature Meter Model: HI8314-1 Manufacturer: Hanna

0765 259 545

The HI9810432 is a professional, accurate and easy to use cordless pH meter from Hanna Instruments. - Specially designed to measure pH directly in cosmetic cream samples - Special junction prevents clogging - Accuracy of ±0.02 pH - Meter comes complete with calibration solutions, rinsing, filling, storage and batteries - Non-removable, pointed glass probe
4490000
Advanced Conductivity Benchtop Meter HI6321 is a streamlined Conductivity/Resistivity/Total Dissolved Solids (TDS)/Salinity/Temperature benchtop meter with a large touch screen display, comprised of a housing and an integrated conductivity measurement module. Compact and easy to operate, the HI6321 includes Hanna’s HI7631233 four-ring conductivity/resistivity/TDS/salinity probe. Recommended for a wide range of industrial process water applications, HI7631233 provides stable measurements over a wide measurement range and does not require frequent calibrations. An integral temperature sensor measures the process temperature and adjusts the measured conductivity to a reference temperature by applying specialized compensation algorithms: Linear: appropriate when it is assumed that the temperature coefficient of variation has the same value for all measurement temperatures. Standard: appropriate for high-purity water measurements and documented in ASTM Standard D5391-14. This setting should be used for >1Mohm.cm resistivity measurements. Natural: appropriate for natural ground, well, or surface water (or water with similar composition) in accordance with ISO7888 standard.