Titration Standard (Standardization, pH/mV default, equivalence point pH/mV)
Direct Read Value
Back Titration (only HI932)
End Point Detection:
Default mV
Default pH
1 equivalence point pH (1st or 2nd derivative)
1 equivalence point mV (1st or 2nd derivative)
BURET
Sizes: 5, 10, 25, and 50 mL
Resolution: 0.001 mL
Pump Speed: 0.3 mL to 2 x buret volume per minute
Accuracy:
±0.005 mL (5 mL buret)
±0.010 mL (10 mL buret)
±0.025 mL (25 mL buret)
±0.050 mL (50 mL buret)
MIXER SYSTEM
Speed Range: 200 to 2500 rpm
Resolution: 100 rpm
pH
Range:
-2.0 to 20.0 pH
-2.00 to 20.00 pH
-2.000 to 20.000 pH
Resolution: 0.1 pH / 0.01 pH
Accuracy (@25ºC/77ºF): ±0.001 pH
Calibration: Maximum of 5 points (select from 8 standard buffer solutions and 5 custom buffer solutions).
Temperature Compensation: Automatic from -5.0 to 105.0°C; 23.0 to 221.0°F
mV
Range: -2000.0 to 2000.0 mV
Resolution: 0.1 mV
Accuracy (@25ºC/77ºF): ±0.1 mV
Calibration: 1 point offset
ISE (Ion-Selective Electrode)
Range: 1 x 10⁻⁶ to 9.99 x 10¹⁰ concentration
Resolution: 1; 0.1; 0.01 concentration
Accuracy:
±0.5% with valence I
±1% with valence II
Calibration: Automatic, calibration up to 5 points, 7 fixed standard solutions available (0.01, 0.1, 1, 10, 100, 1000, 10000 options by concentration) and 5 custom solutions
The HI9810432 is a professional, accurate and easy to use cordless pH meter from Hanna Instruments.
- Specially designed to measure pH directly in cosmetic cream samples
- Special junction prevents clogging
- Accuracy of ±0.02 pH
- Meter comes complete with calibration solutions, rinsing, filling, storage and batteries
- Non-removable, pointed glass probe
Advanced Conductivity Benchtop Meter
HI6321 is a streamlined Conductivity/Resistivity/Total Dissolved Solids (TDS)/Salinity/Temperature benchtop meter with a large touch screen display, comprised of a housing and an integrated conductivity measurement module. Compact and easy to operate, the HI6321 includes Hanna’s HI7631233 four-ring conductivity/resistivity/TDS/salinity probe.
Recommended for a wide range of industrial process water applications, HI7631233 provides stable measurements over a wide measurement range and does not require frequent calibrations. An integral temperature sensor measures the process temperature and adjusts the measured conductivity to a reference temperature by applying specialized compensation algorithms:
Linear: appropriate when it is assumed that the temperature coefficient of variation has the same value for all measurement temperatures.
Standard: appropriate for high-purity water measurements and documented in ASTM Standard D5391-14. This setting should be used for >1Mohm.cm resistivity measurements.
Natural: appropriate for natural ground, well, or surface water (or water with similar composition) in accordance with ISO7888 standard.