Máy đo độ dẫn EC,TDS nhiệt độ HI98318

Máy đo độ dẫn EC,TDS nhiệt độ HI98318

Ứng dụng:

Model: HI98318
Manufacturer: Hanna

Measurement Ranges and Specifications:

  • Conductivity (EC) Range: 0.00 to 6.00 mS/cm

  • Conductivity Resolution: 0.01 mS/cm

  • Conductivity Accuracy: ±2% F.S.

  • TDS Range:

    • 0 to 3000 ppm (500 CF)
    • 0 to 3999 ppm (700 CF)
  • TDS Resolution: 10 ppm (mg/L)

  • TDS Accuracy: ±2% F.S.

  • Temperature Range: 0.0 to 50.0°C / 32.0 to 122.0°F

  • Temperature Resolution: 0.1°C / 0.1°F

  • Temperature Accuracy: ±0.5°C / ±1°F

  • Temperature Compensation: Automatic from 0 to 50°C (32 to 122°F)

  • TDS Conversion Factor: 0.5 (500 ppm) or 0.7 (700 ppm)

Environment:

  • Operating Temperature: 0 to 50°C (32 to 122°F)
  • Humidity: RH max 100%

Dimensions: 160 x 40 x 17 mm (6.3 x 1.6 x 0.7 inches)
Weight: 75 g (2.6 oz.)

Product Similar
Handheld pH/ORP/Temperature Meter Model: HI8314-1 Manufacturer: Hanna

0765 259 545

The HI9810432 is a professional, accurate and easy to use cordless pH meter from Hanna Instruments. - Specially designed to measure pH directly in cosmetic cream samples - Special junction prevents clogging - Accuracy of ±0.02 pH - Meter comes complete with calibration solutions, rinsing, filling, storage and batteries - Non-removable, pointed glass probe
4490000
Advanced Conductivity Benchtop Meter HI6321 is a streamlined Conductivity/Resistivity/Total Dissolved Solids (TDS)/Salinity/Temperature benchtop meter with a large touch screen display, comprised of a housing and an integrated conductivity measurement module. Compact and easy to operate, the HI6321 includes Hanna’s HI7631233 four-ring conductivity/resistivity/TDS/salinity probe. Recommended for a wide range of industrial process water applications, HI7631233 provides stable measurements over a wide measurement range and does not require frequent calibrations. An integral temperature sensor measures the process temperature and adjusts the measured conductivity to a reference temperature by applying specialized compensation algorithms: Linear: appropriate when it is assumed that the temperature coefficient of variation has the same value for all measurement temperatures. Standard: appropriate for high-purity water measurements and documented in ASTM Standard D5391-14. This setting should be used for >1Mohm.cm resistivity measurements. Natural: appropriate for natural ground, well, or surface water (or water with similar composition) in accordance with ISO7888 standard.

0765 259 545