Autoclave SH-AC-128M

Autoclave SH-AC-128M

Ứng dụng:

Autoclave Specifications

  • Maximum Temperature: 130°C (266°F)
  • Operating Pressure Range: 0.1177 to 0.1274 MPa (1.2 to 1.3 kg/cm²)
  • Time Controller: Digital microprocessor-based PID controller
  • Sterilization Time: Adjustable from 0:00 to 99 hours 59 minutes
  • Pressure Gauge: Analog, 0 to 0.3 MPa
  • Temperature Sensor: Pt100
  • Capacity: 128 liters
  • Chamber Dimensions: Diameter Φ500 × Height 650 mm
  • External Dimensions (W × D × H): 700 × 830 × 1365 mm
  • Weight: 140 kg
  • Inner Chamber: Stainless steel
  • Outer Body: Heat-resistant coated steel plate
  • Sterilization Basket: Stainless steel, dimensions Φ468 × 270 mm, weight 3 kg
  • Heating Power: 5 kW
  • Power Supply: 230V, 50/60 Hz, Single Phase
Product Similar
Furnace SH-FU-100TS300/18 SH Scientific 1800℃ high temp tube furnace (100mm diameter tube and 300mm hot zone) - High temp tube furnace with solid door - Double housing and low surface temperature - Recommended ideal running temperature is below 1650℃ - Great durability thanks to SIC heating element and easy replacement of MoSi2 - B type thermocouple - Suitable for gas exchange experiment - Light weight and prompt heat up thanks to ceramic insulation - Built in programmable controller. 5 patterns and 9 segment/pattern. Total 45 segments - Built in over temp protector - SCR operation and built in programmable controller provides low noise operation and precise temp control (+/-1℃) - Wide choice of applicable tube sizes. 50/80/100/120mm diameter. - Wide choice of tube materials. Quartz, ceramic, alumina and alloy

0765 259 545

Furnace Model: SH-FU-11MS(18) 1800℃ high temp muffle furnace (11L) - High-Temperature Furnaces with MoSi2 Rod Heating up to 1800°C - Great for testing metallic sample and sintering - Built in programmable controller. 5 patterns and 9 segment/pattern. Total 45 segments - Recommended ideal running temperature is below 1650℃ *24hours continuous running - Heating from 2 sides and vertical MoSi2 rod preventing warping. Easy replacement - Excellent outgassing thanks to the exhaust air outlet on the head of chamber, i.e plastic polymer - Double housing and low surface temperature - Ceramic fiber materials which are not classified as carcinogenic - Great temp uniformity (+/-4%) - Prompt heat up and good maintaining - SCR operation and programmable control provides low noise operation and precise temp control (+/-1℃) - Gas atmosphere available with optional flow meter

0765 259 545