C406H Oxygen/Water Vapor Transmission Rate Test System

C406H Oxygen/Water Vapor Transmission Rate Test System

C406H Oxygen/Water Vapor Transmission Rate Test System
Model: C406H
Labthink - China
C406H Oxygen /Water Vapor Transmission Rate Test System can be used to test both OTR and WVTR of packaging materials in subsequence at preset temperature and humidity condition.

Ứng dụng:

C406H Oxygen/Water Vapor Transmission Rate Test System
Model: C406H
Labthink - China
Reference Standards
ASTM D3985, ASTM F1307, GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015
ASTM F1249, ISO 15106-2, GB/T 26253, JIS K7129, YBB00092003-2015
Test Applications:
Films
The oxygen and water vapor transmission rate tests of various plastic films, paper-plastic composite films, co-extrusion films, aluminized films, aluminum foil composite films, glass fiber aluminum foil paper composite films and other film-like materials.
Sheets
The oxygen and water vapor transmission rate tests of PP sheet, PVC sheet, PVDC sheet, metal foil, rubber sheet, silicon sheet and other sheet materials.
Technical Specifications
Table 1: Test Parameters Note2
Parameter/Model
Model C406H
OTR Test Range
cc/(m2·day) (Standard area 50cm2)
0.02 ~ 200
cc/(m2·day) (MASK area 5cm2)
0.2 ~ 2000 (Optional)
cc/(m2·day) (MASK area 1cm2)
1 ~ 10000 (Optional)
OTR Resolution
cc/(m2·day)
0.0001
OTR Repeatability
cc/(m2·day)
0.02 or 1%, whichever is greater
WVTR Test Range
g/(m2·day) (Standard area 50cm2)
0.02 ~ 40
g/(m2·day) (MASK area 5cm2)
0.2 ~ 400 (Optional)
g/(m2·day) (MASK area 1cm2)
1 ~ 2000 (Optional)
WVTR Resolution
g/(m2·day)
0.0001
WVTR Repeatability
g/(m2·day)
0.02 or 2%, whichever is greater
Temperature range
°C
15 - 50
5 – 60 (Customized)
Temperature fluctuation
°C
±0.15
Humidity range
%RH (Within standard temperature range)
0%, 5 - 90%±2%, 100%
Extended functions
GP-01 Gas Purification Unit
Optional
DataShieldTM Note3
Optional
Computer System required by GMP
Optional
CFR21 Part11
Optional
Table 2: Technical Specifications
Test Chamber
6 test chambers
Specimen Size
4.6” x 4.6”(11.7cm×11.7cm)
Specimen Thickness
≤120 Mil(3mm)
Standard Test Area
50 cm2
Carrier Gas
99.999% high purity nitrogen, 99.5% oxygen (gas source is out of supply scope)
Carrier Gas Pressure
≥ 40.6 PSI / 280 kPa
Port Size
1/8 inch metal tubing
Power Supply
120VAC±10% 60Hz / 220VAC±10% 50Hz(either one of two)
Instrument Dimensions
23.6” H x 19.2” W x 25.9” D (60cm× 49cm× 66cm)
Net weight
220Lbs(100kg)
Product Similar
ISO 8295, ISO 8510-2, ASTM D1894, ASTM D4917, ASTM D3330, TAPPI T816, TAPPI T549, GB 10006,GB/T 2790,GB/T 2791,GB/T 2792

0765 259 545

C690M Nondestructive Package Leakage Detector Model : C690M Labthink - China C690M Nondestructive Package Leakage Detector is based on the vacuum decay method and pressure decay method, and is designed and manufactured according to ASTM F2338 and other standards. It is professionally suitable for the trace leakage detection of various drug packaging such as vials, ampoule bottles, cartridge bottles, infusion bottle, and prefilled syringes and so on.

0765 259 545

Test Standards ISO 4593, ISO 534, ASTM D6988, ASTM F2251, GB/T 6672, GB/T 451.3, TAPPI T411, BS 2782-6, DIN 53370, ISO 3034, ISO 12625-3, ISO 5084, ASTM D374, ASTM D1777, ASTM D3652, GB/T 6547, GB/T 24218.2, FEFCO No 3, EN 1942, JIS K6250, JIS K6783, JIS Z1702

0765 259 545

- The instrument utilizes the digital preset design of vacuum degree and vacuum retention time to ensure the accuracy of test data - Top quality parts and components made by world famous brands are used to ensure reliable overall product performance - Specimens could be tested in the preset vacuum condition by automatic compensation of constant pressure - Professional software supports automatic back flushing and test termination to provide a safe test environment - The instrument is controlled by micro-computer, with LCD and PVC operation panel, which is convenient for customers to test and view test data

0765 259 545

BTY-B3P Gas Permeability Tester Model: BTY-B3P BTY-B3P Gas Permeability Tester is based on the differential pressure method, and is professionally applicable to the determination of gas permeability of battery diaphragms, breathable films and other relative polymer products.

0765 259 545

Features - Based on the positive pressure method and controlled by micro-computer, with LCD, menu interface and PVC operation panel - Dual test methods of restraint distension and unrestraint distension for customer's free choice - Different test modes of burst, creep, and creep to failure to meet different test requirements - Optional test range, "one key operation" and other intelligent designs support combinations of non-standard test conditions - Professional software provides automatic statistics of test data - Equipped with micro-printer and standard RS232 port for convenient PC connection and data transfer - Supports LystemTM Lab Data Sharing System for uniform and systematic management of test results and test reports Standards - This test instrument conforms to the following standards: ISO 11607-1, ISO 11607-2, GB/T 10440, GB 18454, GB 19741, GB 17447, ASTM F1140, ASTM F2054, GB/T 17876, GB/T 10004, BB/T 0025, QB/T 1871, YBB 00252005, YBB 00162002

0765 259 545

- Equipped with Labthink self-developed coulometric sensor conforming to ASTM D3985, intrinsic standard and no calibration is required - Support temperature control to satisfy tests under different conditions (optional) - Built-in high-quality stainless steel test cell with better sealing performance - Imported manual isolation valve and flow regulator are adopted for better sealing performance and lower failure rate - Industrial computer appearance design, small size and fast cooling - Reference film is provided for quick calibration - The system adopts single-chip microcomputer control and can run independently - The test report can be exported in common formats such as EXCEL and PDF - Support micro printer, automatically print test data (optional) - Equipped with RS232 data interface, which can be connected to computer software for curve analysis, data storage, report printing, etc. (optional) - The gas purifier independently developed by Labthink can remove trace oxygen in nitrogen and provide oxygen-free carrier gas (optional). - Standard ASTM D3985、ASTM F1307、GB/T 19789、GB/T 31354、DIN 53380-3、JIS K7126-2-B、YBB 00082003-2015

0765 259 545