pH/Temperature Benchtop Meter HI2211-02

pH/Temperature Benchtop Meter HI2211-02

pH/Temperature Benchtop Meter HI2211-02

Ứng dụng:

pH/Temperature Benchtop Meter HI2211-02

  • pH Range: -2.00 to 16.00 pH
  • pH Resolution: 0.01 pH
  • pH Accuracy: ±0.01 pH
  • mV Range: ±399.9 mV; ±2000 mV
  • mV Resolution: 0.1 mV; 1 mV
  • mV Accuracy: ±0.2 mV (±399.9 mV); ±1 mV (±2000 mV)
  • Temperature Range: -9.9 to 120°C
  • Temperature Resolution: 0.1°C
  • Temperature Accuracy: ±0.5°C (0.0 - 100.0°C); ±1°C (outside of this range)
  • pH Calibration: Automatic at 1 or 2 points with standard pH values (pH 4.01, 6.86, 7.01, 9.18, 10.01)
  • Automatic Temperature Compensation: Yes
  • pH Electrode: HI 1131B, glass, BNC connection, 1m cable
  • Temperature Electrode: HI 7662, 1m cable, Input Impedance 10¹² Ohm
  • Power Supply: 12 VDC adapter (included)
  • Operating Environment: 0 - 50°C (32 - 122°F); RH max 95%
  • Dimensions: 240 x 182 x 74 mm (9.4 x 7.1 x 2.9")
  • Weight: 1.1 kg (2.5 lb)
Product Similar
Handheld pH/ORP/Temperature Meter Model: HI8314-1 Manufacturer: Hanna

0765 259 545

The HI9810432 is a professional, accurate and easy to use cordless pH meter from Hanna Instruments. - Specially designed to measure pH directly in cosmetic cream samples - Special junction prevents clogging - Accuracy of ±0.02 pH - Meter comes complete with calibration solutions, rinsing, filling, storage and batteries - Non-removable, pointed glass probe
4490000
Advanced Conductivity Benchtop Meter HI6321 is a streamlined Conductivity/Resistivity/Total Dissolved Solids (TDS)/Salinity/Temperature benchtop meter with a large touch screen display, comprised of a housing and an integrated conductivity measurement module. Compact and easy to operate, the HI6321 includes Hanna’s HI7631233 four-ring conductivity/resistivity/TDS/salinity probe. Recommended for a wide range of industrial process water applications, HI7631233 provides stable measurements over a wide measurement range and does not require frequent calibrations. An integral temperature sensor measures the process temperature and adjusts the measured conductivity to a reference temperature by applying specialized compensation algorithms: Linear: appropriate when it is assumed that the temperature coefficient of variation has the same value for all measurement temperatures. Standard: appropriate for high-purity water measurements and documented in ASTM Standard D5391-14. This setting should be used for >1Mohm.cm resistivity measurements. Natural: appropriate for natural ground, well, or surface water (or water with similar composition) in accordance with ISO7888 standard.