Advanced Conductivity Benchtop Meter
HI6321 is a streamlined Conductivity/Resistivity/Total Dissolved Solids (TDS)/Salinity/Temperature benchtop meter with a large touch screen display, comprised of a housing and an integrated conductivity measurement module. Compact and easy to operate, the HI6321 includes Hanna’s HI7631233 four-ring conductivity/resistivity/TDS/salinity probe.
Recommended for a wide range of industrial process water applications, HI7631233 provides stable measurements over a wide measurement range and does not require frequent calibrations. An integral temperature sensor measures the process temperature and adjusts the measured conductivity to a reference temperature by applying specialized compensation algorithms:
Linear: appropriate when it is assumed that the temperature coefficient of variation has the same value for all measurement temperatures.
Standard: appropriate for high-purity water measurements and documented in ASTM Standard D5391-14. This setting should be used for >1Mohm.cm resistivity measurements.
Natural: appropriate for natural ground, well, or surface water (or water with similar composition) in accordance with ISO7888 standard.
- Dual Mode Portability: Traditional Operation, or ISO / ANSI Mode Operation (optional auto-optic required)
- Non-Contact Point-and-Shoot Bar Code Capture
- Print Gain Measurement ï Auto-discriminates Between All Popular Symbologies
- Multiple Scan Averaging
- Follows the ISO15416 and ANSI X3.182 Bar Code Inspection Methods (auto-optic scan head only)
- Conforms to ISO15426-1 Bar Code Verifier Specification (auto-optic scan head only)
- Option for Full ISO/ANSI inspection and Reporting
- This flexible and cost-effective unit is also easy to use, and supports all popular linear symbologies. The RJS D4000 offers store and print capability, multiple scan averaging, and sub-symbology choices - all easily accessible through a simple four-button user interface.
- Bar code analysis information appears immediately on the 32-character alphanumeric liquid crystal display(LCD), and a distinct audible tone and a series of five colored LEDs indicate whether a bar code is in or out of specification. In addition to the ISO/ANSI method parameters, Traditional Analysis parameters are provided on the LCD, without a special mode setting.
The MA160 series is ideal for moisture analysis of a wide variety of samples. Typical applications include moisture analysis of foods, beverages, pharmaceuticals, chemicals, paper materials and environmental humidity determination.
Food Metal detector
Model : CQ-810
Guangdong - China
Performance characteristics:
◆This machineis madeofall stainlesssteel304. The conveyorbel tadopts white non-toxic food grades pecial sanita rycon veyor belt which meets the American "FDA" standard;
◆The digital machine is fully functional with memory function. Can store 12 kinds of pro duct testing para meters;
◆ Two-way signal detection circuit combining technology, LCD liquid crystal display, Chine seand English menu-styles creen,easytoim plement operation;
◆Adopting German pro fessional testing technology and balan cedprinci ple, the detec tionaccuracy is high, and the working condition can be more stable and reliable.
◆ The insufficiency of the complementary simulator, the DSP and the single-chipmicro computer combine the data sampling and data processing of the detection signal toimprove the detection effect.
◆ New circuit design, with high detection sensitivity and phase adjustment
technology, which can adjust the product and effectively suppress the product effect;
◆It can detectiron,non-iron,stainless steel,copperan daluminum,and non-ferrous metals.
◆With self-learning ability, it has a wide range of detection materials and has stronganti-interference and shock resistance.
◆ Motor speed is 26 meters per minute and supports 24 hours of uninterrup tedwork.
◆Good water proofper formance,suita blefor humid,coldstoragean dother environ ments.
inhole Tester for Aluminum Foil (also known as the Light Box), is an equipment which can help detect pin holes in aluminum foils used in food and pharmaceutical packaging.
Pinholes are micro leaks in the foil surface which can reduce the shelf life or stability of the product they are used to protect.
Principle of Operation :
Leak Test : Air is injected into the package and internally pressurized up to a set pressure and held
for a set time. The equipment will automatically detect leakages by monitoring the pressure drop.
Additionally, if the package is tested when held under water, you will also see air bubbles from leak
points. Even micro leakages which the equipment cannot detect via pressure drop, can be visible
under water, making it a very reliable test.
Burst Test : Air is injected into the package and internally pressurized until the sample bursts. The
max burst pressure is displayed. This is considered as a 360 Seal Strength / Seal Integrity Test.
Additionally, you can identify the weakest point of your package as it will fail first.
Leak Burst Test : A combination of the above 2 tests. First the Leak Test will happen. If the package
FAILS in Leak Test, the test is abandoned. If the package passes the Leak Test, it is automatically
subjected to the Burst Test. So you can do 2 test on the same package, while saving time on sample
preparation. And of course, you waste less samples.
Pouch Press Tester
Test Type : Press till Load Setpoint. Hold till Time Setpoint.
In this method, the sample is compressed upto a preset Load. The applied force is held on the pouch
for preset time. After the times elapses, the machine returns to the original position.
Features
Equipped with a digital display and a decoder for height recording, to accurately detect the drop height, and the tolerance will not exceed 2% or 10MM.
Adopt single-arm structure, with electric lift and down function.
This machine has the advantages of low impact vibration, stable and reliable.
Apply standard
ISO 2248-1972E
JIS Z0202-87
GB4757.5-84
2100Q Handheld Turbidity Meter
Model: 2100Q
Manufacturer: Hach - USA
The 2100Q will guide you through calibration and verification directly on the screen by displaying all the key information needed to perform the measurement on the screen.
In full calibration mode (0 to 1000 NTU), calibration instructions will be provided for you to follow easily step by step as well as verify the accuracy of the calibration automatically. This support eliminates the need for manuals and ensures that the calibration is completed and meets the requirements.
Measurement results through the Verify Cal function (calibration verification) are quick and easy when used with the 10 NTU StablCal primary standard solution
Kjeldahl Crusher SH420F
Model: SH420F
Manufacturer: Hanon
Origin: China
Hanon SH420F Kjeldahl Digestor adopts advanced high-temperature infrared tradiation heating technology and microprocessor control platform, boasts accurate temperature control and quick temperature rise. It has two kinds of temperature rise modes: linear and curve temperature rise mode, and offers 25 digestion programs for control of temperature rise curves.
Neutralization system has many functions such as triple filtration, condensate recovery of exhaust gas, filtration and neutralization device. The product adopts high-quality anticorrosive pumps, low noise, strong suction, reduce exhaust emissions, eco-friendly.
Veego 8 Position Dissolution Tester, VDA-8D
Product Code: VDA-8D
Origin: India
Product Description
Tablet Dissolution Test Apparatus is an easy-to-use test instrument that is designed to accurately measure the dissolving rate of solid oral medications such as tablets and capsules. This high-performance testing machine is important for asses the bioavailability of various types of drugs. It is equipped with durable vessels, a motor-driven basket, and a temperature control system. The sturdy mild steel body of this unit makes it capable to bear extreme working conditions. It can be delivered to our clients as per their demands with the assurance of fast and safe delivery at a reasonable price.