Máy Phân Tích COD Và Đa Chỉ Tiêu Trong Nước Thải Và Nước Sạch HI83399-02

Máy Phân Tích COD Và Đa Chỉ Tiêu Trong Nước Thải Và Nước Sạch HI83399-02

Ứng dụng:

  1. pH Electrode: Digital pH electrode (sold separately)
  2. Recording Type: On-demand recording with user name and sample ID
  3. Recording Memory: 1000 samples
  4. Connectivity: USB-A host for flash drive; micro-USB-B for power and computer connectivity
  5. GLP: Calibration data for pH electrode
  6. Display: LCD with backlight, 128 x 64 resolution
  7. Battery: Rechargeable 3.7VDC battery
  8. Power Supply: 5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included)
  9. Operating Environment: 0 to 50°C (32 to 122°F); max 95% RH, non-condensing
  10. Dimensions: 206 x 177 x 97 mm
  11. Weight: 1.0 kg
  12. Light Source: 5 LED lights at 420 nm, 466 nm, 525 nm, 575 nm, and 610 nm
  13. Light Detector: Silicon photodetector
  14. Bandpass Filter Bandwidth: 8 nm
  15. Bandpass Filter Wavelength Accuracy: ±1 nm
  16. Cuvette: Round 24.6 mm (sample tubes 16 mm)
  17. Number of Methods: Up to 128
Product Similar
Handheld pH/ORP/Temperature Meter Model: HI8314-1 Manufacturer: Hanna

0765 259 545

The HI9810432 is a professional, accurate and easy to use cordless pH meter from Hanna Instruments. - Specially designed to measure pH directly in cosmetic cream samples - Special junction prevents clogging - Accuracy of ±0.02 pH - Meter comes complete with calibration solutions, rinsing, filling, storage and batteries - Non-removable, pointed glass probe
4490000
Advanced Conductivity Benchtop Meter HI6321 is a streamlined Conductivity/Resistivity/Total Dissolved Solids (TDS)/Salinity/Temperature benchtop meter with a large touch screen display, comprised of a housing and an integrated conductivity measurement module. Compact and easy to operate, the HI6321 includes Hanna’s HI7631233 four-ring conductivity/resistivity/TDS/salinity probe. Recommended for a wide range of industrial process water applications, HI7631233 provides stable measurements over a wide measurement range and does not require frequent calibrations. An integral temperature sensor measures the process temperature and adjusts the measured conductivity to a reference temperature by applying specialized compensation algorithms: Linear: appropriate when it is assumed that the temperature coefficient of variation has the same value for all measurement temperatures. Standard: appropriate for high-purity water measurements and documented in ASTM Standard D5391-14. This setting should be used for >1Mohm.cm resistivity measurements. Natural: appropriate for natural ground, well, or surface water (or water with similar composition) in accordance with ISO7888 standard.